ASTM E1105:
Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform or Cyclic Static Air Pressure Difference

ASTM E1105: Determining the Resistance of Windows, Curtain Walls, Skylights, and Doors to Water Penetration

During ASTM E1105 field testing, water is applied to the outdoor face and exposed edges simultaneously with static air pressure. The ASTM E1105 testing can be applied to any curtain wall area or to windows, skylights, or doors alone. It is intended to determine the resistance to water penetration through specified building assemblies. If water does penetrate the assembly, but does not result in failure it may have ill effects on the performance of the materials, sealant, insulation, or laminated glass. However, ASTM E1105 is not used to address these issues or concerns.

Conducting ASTM E1105 Testing

The best time to conduct the ASTM E1105 field testing is after the window, skylight, curtain wall, or door assemblies are initially installed and before interior work has been completed. By conducting the testing before interior work is complete, testers have easier access to the surfaces and can identify water penetration. Otherwise, parts of the interior materials will need to be removed in order to conduct the actual water penetration testing.

To conduct the actual testing, a valve on the water-spray system is adjusted so that the intake water is being delivered at the calibrated pressure. The water pressure and rate must be maintained for 15 minutes over the testing area. During the test, the interior of the wall is observed and the tester will take note of any water penetration. After the 15 minutes are over, stop the water spray and inspect the area for any additional evidence of water penetration.

Water leak testing helps keep your building safe.

The Benefits of ASTM E1105 Testing from TSI Energy Solutions

TSI uses the latest testing technologies to ensure accurate procedures and precise results.   TSI’s technicians travel the country testing many types of systems under various climactic conditions which gives us the critical knowledge and experience necessary to perform these tests.

TSI Energy Solutions Expertise in ASTM E1105 Testing

TSI’s testing team performs inspections throughout the country so we see various types of construction in all conditions.  TSI has tested hundreds of commercial buildings over our 35 plus year history.   Most of our technicians have been with our company for 10-25 years so they offer unrivaled experience.

How to Get Started With ASTM E1105 Testing

At TSI Energy Solutions, we understand your need to make sure your building is watertight. When water penetrates your curtain wall, the structure of your building can be compromised. We make getting the ASTM E1105 testing you need easy.

Step 1: Contact our experts by filling out the form and letting us know about your project’s details.

Step 2: Identify the area of your building to be tested.

Step 3: Watch as our experts test the water resistance of your curtain wall.  