ASTM E783:
Field Measurement of Air Leakage Through Installed Exterior Windows and Doors

ASTM E783: Determining Air Leakage Rates of Installed Exterior Windows and Doors

The purpose of the ASTM E783 field measurement test is to determine the leakage associated with the assembly and not the opening between the assemblies. The method is used to create natural environmental conditions that induce air leakage. During the actual test, a chamber is sealed over the interior or exterior face of a testing specimen. The chamber supplies air to or exhausts air at a rate required to maintain test pressure. As the pressure is adjusted, the airflow across the test specimen is recorded.

Conducting ASTM E783 Field Measurements

During the ASTM E783 field measurement of air leakage, a test chamber is fitted to the perimeter of the predetermined test specimen. The test chamber must completely cover the entire assembly. Joints, cracks, and opening for which air leakage is not to be determined must be sealed to prevent leakage from skewing final testing results. The extraneous air leakage through and around the chamber, apparatus, and specimen needs to be measured.

To test the air leakage, the air flow through the test chamber is adjusted to different pressures across the test specimen. When test conditions are stable, the airflow is recorded. Other measurements including barometric pressure, temperature, and relative humidity must be collected near the air intake or exhaust of the air system.

ASTM E783 chamber testing finds the air leakage sites in commercial buildings.

The Benefits of ASTM E783 Testing from TSI Energy Solutions

TSI uses the latest testing technologies to ensure accurate procedures and precise results.   TSI’s technicians travel the country testing many types of systems under various climactic conditions which gives us the critical knowledge and experience necessary to perform these tests.

TSI Energy Solutions Expertise in ASTM E783 Testing

TSI’s testing team performs inspections throughout the country so we see various types of construction in all conditions.  TSI has tested hundreds of commercial buildings over our 35 plus year history.   Most of our technicians have been with our company for 10-25 years so they offer unrivaled experience.

How to Get Started With AAMA 783 Testing

At TSI Energy Solutions, we know how air leakage impacts your building and we understand your need to minimize leaks. Our ASTM E783 testing helps you identify these leaks and get them corrected. Getting started is easy.

Step 1: Fill out the form and let TSI know about your testing needs.

Step 2: Identify the area that you want to test for air leakage.

Step 3: Watch as our experts set up a testing chamber and check for air leaks. 

Fields marked with an * are required